TRANSPORT AND MAGNETIC AC LOSSES IN AG TL-1223 TAPE AND THE EFFECT OFMECHANICAL DAMAGE/

Citation
M. Ciszek et al., TRANSPORT AND MAGNETIC AC LOSSES IN AG TL-1223 TAPE AND THE EFFECT OFMECHANICAL DAMAGE/, Journal of superconductivity, 11(1), 1998, pp. 145-146
Citations number
1
Categorie Soggetti
Physics, Applied","Physics, Condensed Matter
ISSN journal
08961107
Volume
11
Issue
1
Year of publication
1998
Pages
145 - 146
Database
ISI
SICI code
0896-1107(1998)11:1<145:TAMALI>2.0.ZU;2-T
Abstract
In this paper we present the results of AC loss measurements on silver clad monocore tapes of Tl-1223 prepared by the powder-in-tube method. Losses arising from an external AC magnetic field are compared with t hose generated by AC transport currents (self-field losses). Critical current densities are derived from magnetic loss data and compared wit h those measured by the four point transport method. It was found that mechanically induced stresses (introduced by bending) only have a sig nificant effect on the transport losses, via the critical current degr adation. Such changes are not seen in measured magnetic losses, which are independent of mechanical stress, and remain unchanged, at least i n the stress range used in our experiment.