OPERATING RESULTS OF THE SOLIAC FLORANGE TANK DEGASSING UNIT AFTER 3 YEARS OF PRODUCTION

Citation
F. Chatelain et al., OPERATING RESULTS OF THE SOLIAC FLORANGE TANK DEGASSING UNIT AFTER 3 YEARS OF PRODUCTION, Revue de métallurgie, 95(1), 1998, pp. 17
Citations number
4
Categorie Soggetti
Metallurgy & Metallurigical Engineering
Journal title
Revue de métallurgie
ISSN journal
00351563 → ACNP
Volume
95
Issue
1
Year of publication
1998
Database
ISI
SICI code
Abstract
A tank degasser has been commissioned in 1994 at the Sollac Florange s teel plant. After three years of production, this unit produces many d ifferent grades : ultra-low carbon grades for IF steel and ultra-low h ydrogen steels for rail grades. The production is now about 60 to 70 k t per month of decarburized grades for slab continuous casting and 25 to 30 kt per month of dehydrogenized grades for bloom continuous casti ng.