COMPARISON OF DIFFERENT METHODS FOR THE DETERMINATION OF THE WATER-CONTENT AND THE DRY MASS CORRECTION FACTOR IN VARIOUS PLANT-SAMPLES

Citation
S. Stegen et al., COMPARISON OF DIFFERENT METHODS FOR THE DETERMINATION OF THE WATER-CONTENT AND THE DRY MASS CORRECTION FACTOR IN VARIOUS PLANT-SAMPLES, Fresenius' journal of analytical chemistry, 360(5), 1998, pp. 601-604
Citations number
14
Categorie Soggetti
Chemistry Analytical
ISSN journal
09370633
Volume
360
Issue
5
Year of publication
1998
Pages
601 - 604
Database
ISI
SICI code
0937-0633(1998)360:5<601:CODMFT>2.0.ZU;2-0
Abstract
The water content was measured by microwave-, oven-, and freeze-drying in different vegetables like beans, corn, potato, alfalfa, garlic, an d onions. Apart from beans and bean shells, all procedures resulted in similar values, Oven-drying seemed to be less suitable for beans. In samples which were in equilibrium with the laboratory environment for a longer time, the correction factor to dry mass was determined using a freeze-drying device, infrared-, microwave-and oven-drying. All the procedures yielded similar values for this factor.