A FACILITY FOR ELECTRICAL CONTACT RESISTANCE MEASUREMENT

Citation
Hd. Maheshappa et al., A FACILITY FOR ELECTRICAL CONTACT RESISTANCE MEASUREMENT, Review of scientific instruments, 69(3), 1998, pp. 1534-1536
Citations number
5
Categorie Soggetti
Physics, Applied","Instument & Instrumentation
ISSN journal
00346748
Volume
69
Issue
3
Year of publication
1998
Pages
1534 - 1536
Database
ISI
SICI code
0034-6748(1998)69:3<1534:AFFECR>2.0.ZU;2-D
Abstract
A test facility was developed for directly measuring the electrical co ntact resistance of switch gear contacts of real sizes under different environmental conditions and contact pressures. It can measure contac t resistance to an order of one-tenth of a mu Omega. It sources a cons tant current in the order of mA and hence avoids Initial arcing across contacts, Experiments were conducted on brass-brass samples with diff erent contact pressures and the results are in agreement with publishe d theoretical calculations. (C) 1998 American Institute of Physics.