This article details the authors' experience with a relatively unknown
technique for covering exposed ends of transscleral sutures, During c
ombined transscleral suturing of a posterior chamber intraocular lens
(PC IOL) with a penetrating keratoplasty, buttons from the excised rec
ipient cornea are sutured with 10-0 nylon over the protruding suture e
nds. This technique has been used successfully in four cases.