T. Watanabe et al., SIMULTANEOUS DETERMINATION OF CHLORINE DIOXIDE AND HYPOCHLORITE IN WATER BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY, Journal of chromatography, 796(2), 1998, pp. 397-400
Citations number
12
Categorie Soggetti
Chemistry Analytical","Biochemical Research Methods
The simultaneous determination of chlorine dioxide and hypochlorite by
high-performance liquid chromatography was developed. The chromogenic
substance formed by the oxidation-condensation reaction using 4-amino
antipyrine (4-AA) and phenol was determined at 503 nm by a post-column
reaction system. Chlorine dioxide and hypochlorite were separated wit
hin 3 min by applying the elution solution (1.7 mM sodium carbonate-1.
8 mM sodium carbonate) at 0.5 mi/min into a laboratory-prepared PTFE t
ube column (13 cmx1.0 mm I.D.x2 mm O.D.) packed with Waters Accell QMA
as the anion-exchange material. A linear correlation between the peak
height and concentration was obtained within the range of 1-20 mu g/m
l for chlorine dioxide and 47-200 mu g/ml for hypochlorite, with good
reproducibility (relative standard deviations of 4.0 and 2.2%, respect
ively, replicated determination). The limits of detection of chlorine
dioxide and hypochlorite were approximately 0.2 and 10 mu g/ml (SIN=3)
, respectively. (C) 1998 Elsevier Science B.V.