Various sources for the rf-dc differences of micropotentiometers (micr
opots) are analyzed and calculated, The results are shown to agree wel
l with experimental values, A new design is introduced that reduces th
e rf-de differences of the micropots significantly. Observations show
good stability over a long period. This makes the micropot suitable as
a primary rf and audio standard in the microvolt and millivolt ranges
.