ON THE NOISE BEHAVIOR OF DMILL CHARGE AND CURRENT-SENSITIVE PREAMPLIFIER ARCHITECTURES

Citation
J. Ardelean et al., ON THE NOISE BEHAVIOR OF DMILL CHARGE AND CURRENT-SENSITIVE PREAMPLIFIER ARCHITECTURES, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 406(1), 1998, pp. 127-138
Citations number
3
Categorie Soggetti
Nuclear Sciences & Tecnology","Physics, Particles & Fields","Instument & Instrumentation",Spectroscopy
ISSN journal
01689002
Volume
406
Issue
1
Year of publication
1998
Pages
127 - 138
Database
ISI
SICI code
0168-9002(1998)406:1<127:OTNBOD>2.0.ZU;2-J
Abstract
Novel configurations of current and voltage-sensitive preamplifiers in DMILL technology intended for calorimetry applications are discussed. A broad set of noise characterisation tests: including room temperatu re, cryogenic operation and radiation effects, is given. It is shown t hat in cryogenic conditions the noise behaviour is considerably less c urrent dependent than at room temperature. (C) 1998 Elsevier Science B .V. All rights reserved.