APPARATUS FOR AC LOSS MEASUREMENT IN SUPE RCONDUCTING WIRES

Citation
S. Lenaour et al., APPARATUS FOR AC LOSS MEASUREMENT IN SUPE RCONDUCTING WIRES, EUROPEAN PHYSICAL JOURNAL-APPLIED PHYSICS, 1(1), 1998, pp. 135-138
Citations number
11
Categorie Soggetti
Physics, Applied
ISSN journal
12860042
Volume
1
Issue
1
Year of publication
1998
Pages
135 - 138
Database
ISI
SICI code
1286-0042(1998)1:1<135:AFALMI>2.0.ZU;2-D
Abstract
A thermometric apparatus to measure AC losses in superconductor wires for 50 Hz applications is described. This method consists in isolating the sample from a helium bath via a thermal resistance. Dissipated po wer is determined by two thermometers located on both edges of a therm al resistance. The measurement's calibration is done using an ohmic he ater. The measurement accuracy is 10% for losses in excess of 2 mW/m.