HEAT-EXCHANGER PERFORMANCE - INFLUENCE OF GAP WIDTH BETWEEN CONSECUTIVE VERTICAL RECTANGULAR FIN-ARRAYS

Citation
Cw. Leung et Sd. Probert, HEAT-EXCHANGER PERFORMANCE - INFLUENCE OF GAP WIDTH BETWEEN CONSECUTIVE VERTICAL RECTANGULAR FIN-ARRAYS, Applied energy, 56(1), 1997, pp. 1-8
Citations number
9
Categorie Soggetti
Energy & Fuels","Engineering, Chemical
Journal title
ISSN journal
03062619
Volume
56
Issue
1
Year of publication
1997
Pages
1 - 8
Database
ISI
SICI code
0306-2619(1997)56:1<1:HP-IOG>2.0.ZU;2-C
Abstract
Two identical rectangular heat-exchanger fin-arrays, with their bases in the same vertical plane, arranged in series one above the other, we re used instead of a single array of double the original length fins t o dissipate heat from a vertical rectangular base, which was kept at 4 0 degrees C above the ambient environment. The effect of the magnitude of the gap width between the two consecutive arrays, upon the steady- state rate of hear transfer from the heated base of the exchanger unde r natural-convection conditions, was investigated experimentally. When a gap width of 18 +/- 2 mm is used, a saving in fin material ensues t ogether with a slight (similar to 3%) increase in the rate of heat dis sipation, being achieved. (C) 1997 Elsevier Science Ltd.