Bl. Gong et al., COMPARISON OF CHEMICAL MODIFIERS USED FOR THE DETERMINATION OF GOLD IN ORES BY ELECTROTHERMAL ATOMIC-ABSORPTION SPECTROMETRY, Analytica chimica acta, 362(2-3), 1998, pp. 247-251
The interference effects of major matrix elements, contained in gold o
res (silicate-, oxide-, sulfide-, bismuth- and tellurium-ores) for the
determination of gold by electrothermal atomic absorption spectrometr
y (ETAAS), were studied. Samples of five one-component (Cu, Mo, Ni, Pd
and V) and 12 two-component chemical modifiers composed from above fi
ve one-component modifiers were compared for their anti-interference e
ffects on the major matrix elements (Al, As, Bi, Ca, Cu, Fe, Mg, Mn, P
b, Sb, Te and Zn) in gold ores. A chemical-modifier solution composed
of 1000 mg l(-1) each of Ni and V showed the best performance. Gold in
five decoppered copper oxide ores was determined by ETAAS with the he
lp of the Ni/V chemical modifier without matrix pre-separation. The re
lative standard deviation was 3.9% (n=9) for 0.47 mg l(-1) gold. The r
ecoveries of added gold (50 mg l(-1)) were 93-102%. The characteristic
mass was 12.8 pg. (C) 1998 Elsevier Science B.V.