Sm. Anderton et al., DETERMINATION OF BLOOD-GLUCOSE BY QUANTITATIVE TLC ON PREADSORBENT SILICA-GEL PLATES, Journal of liquid chromatography & related technologies, 21(7), 1998, pp. 1045-1049
Citations number
5
Categorie Soggetti
Chemistry Analytical","Biochemical Research Methods
A thin layer chromatography method was developed for quantification of
glucose in human blood serum using preadsorbent silica gel plates, ac
etonitrile-water (85:15) mobile phase, methanolic sulfuric acid detect
ion reagent, and scanning densitometry. Results are reported for the m
easurement of glucose by the TLC method before and after consumption o
f a sucrose solution. The method was validated by determining the prec
ision for replicate analyses and accuracy by analyzing a spiked sample
and also comparing results with those given by a commercial kit inten
ded for use by diabetics for home monitoring of glucose levels. The TL
C method is simple to perform and can serve for the analysis of other
sample types and as an interesting experiment illustrating quantitativ
e TLC in college analytical chemistry or biochemistry laboratory cours
es.