LARGE-SCALE TESTS OF INSULATED CONDUIT FOR THE ITER CS COIL

Citation
Rp. Reed et al., LARGE-SCALE TESTS OF INSULATED CONDUIT FOR THE ITER CS COIL, Cryogenics, 38(1), 1998, pp. 33-38
Citations number
1
Categorie Soggetti
Physics, Applied",Thermodynamics
Journal title
ISSN journal
00112275
Volume
38
Issue
1
Year of publication
1998
Pages
33 - 38
Database
ISI
SICI code
0011-2275(1998)38:1<33:LTOICF>2.0.ZU;2-U
Abstract
Compression-fatigue tests at 77 K were conducted on test modules of in sulated Incoloy 908 conduit. To replicate the operating conditions for the ITER central solenoid (CS) full-scale coil, fatigue loads up to 3 .6 MN were applied for 10(5) cycles; no mechanical breakdowns occurred . The conduits were insulated with a preimpregnated resin system, a te traglycidyl diaminodiphenyl methane (TGDM) epoxy cured with DDS aromat ic amine. The conduits were joined by vacuum-pressure impregnation wit h a diglycidyl ether of bisphenol-F epoxy/anhydride-cured resin system . In the 4 x 4 stacked-conduit test modules, the layer insulation (a h igh-pressure laminate of TGDM epoxy cured with DDS aromatic amine) was inserted. Periodically during the tests, breakdown voltage was measur ed across the conduits of both turn and layer insulation; throughout t he test, breakdown voltages were at least 46 kV. The addition of a bar rier increased structural and electrical reliability. (C) 1998 Elsevie r Science Ltd. All rights reserved.