Hs. Shin et al., ASSAY OF MIDAZOLAM IN HUMAN PLASMA BY GAS-LIQUID-CHROMATOGRAPHY WITH NITROGEN-PHOSPHORUS DETECTION, Bulletin of the Korean Chemical Society, 19(5), 1998, pp. 524-526
A sensitive and specific method is described for the determination of
midazolam in human plasma. The drug was extracted from 1 mL of carbona
te buffered plasma (pH 9.6) with 8 mt of diethyl ether. Famprofazone w
as used as internal standard. The organic phase was evaporated to dryn
ess. The residue was dissolved in methanol for the direct analysis by
gas chromatograph-nitrogen phosphorus detector system. In the concentr
ation range of 1-5000 ng/mL, the calibration curve was linear. The coe
fficients of variation from the precision test were <6% at the range o
f the concentration of 0.10-2.00 mu g/mL and the detection limit for m
idazolam in 1 mL of plasma was 0.5 ng. This assay is more sensitive, s
elective, simple and rapid than earlier methods. Plasma midazolam conc
entrations were determined by this method after administration of mida
zolam.