APPLICATION OF HIGH-TENSION ANNEALING TO NYLON-46 FIBERS

Citation
A. Suzuki et al., APPLICATION OF HIGH-TENSION ANNEALING TO NYLON-46 FIBERS, Polymer Journal, 30(4), 1998, pp. 275-280
Citations number
40
Categorie Soggetti
Polymer Sciences
Journal title
ISSN journal
00323896
Volume
30
Issue
4
Year of publication
1998
Pages
275 - 280
Database
ISI
SICI code
0032-3896(1998)30:4<275:AOHATN>2.0.ZU;2-A
Abstract
To improve the tensile properties of nylon 46 fibers, high-tension ann ealing (HTA) was applied to nylon 46 fibers previously treated with hi gh-temperature zone-drawing. Fibers produced by the high-temperature z one-drawing treatment had a tensile modulus of 7.2 GPa and tensile str ength of 1.0 GPa. Two HTA treatments were carried out; the first (HTA1 ) treatment at 100 degrees C under an applied tension of 538.2 MPa, an d the second (HTA2) treatment at 150 degrees C under 568.0 MPa. The fi bers obtained finally had a tensile modulus of 8.4 GPa, tensile streng th of 1.2 GPa and a storage modulus of 11.2 GPa at 25 degrees C.