T. Ebefors et al., DYNAMIC ACTUATION OF POLYIMIDE V-GROOVE JOINTS BY ELECTRICAL HEATING, Sensors and actuators. A, Physical, 67(1-3), 1998, pp. 199-204
New robust three-dimensional silicon structures with integrated heater
s for dynamic actuation have been fabricated and tested. The structure
s can be used in both static and dynamic modes for 3-D sensor and actu
ator applications. The proposed technique for bending 3-D structures o
ut of the wafer plane is based on thermal shrinkage of polyimide in V-
grooves, producing static bending. This static angle can be chosen in
a wide range by varying the curing temperature. The relatively large t
hermal expansion of polyimide makes it possible to use the structure i
n dynamic mode. A local power dissipation in the joint is achieved by
using a current through an integrated heater. This makes it possible t
o control the bending angle of each individual structure. For the test
ed polyimide V-groove joints, static bending angles of 35 degrees and
dynamic angles of 3 degrees per V-groove have been achieved. (C) 1998
Elsevier Science S.A. All rights reserved.