L. Sandstrom et al., GAS MONITORING USING SEMICONDUCTOR-LASERS OPERATING IN THE 2 MU-M WAVELENGTH REGION, Infrared physics & technology, 39(2), 1998, pp. 69-75
Measurements of ammonia (NH3) and carbon dioxide (CO2) using a Fabry-P
erot strained layer quantum well laser operating at 1.94 mu m have bee
n made. Fourier-transform infrared (FTIR) measurements, in the 1.4-2.1
mu m region, were also made in order to compare the strength of diffe
rent absorption bands of NH3 and CO2. The FTIR measurements showed tha
t the absorption line intensities for NH3 and CO2 in the 2 mu m wavele
ngth region were up to two orders of magnitude stronger than the line
intensities in the 1.5 mu m region. An NH3 sensitivity of 3 ppm . m, a
t atmospheric pressure, using 1 Hz detection bandwidth, is demonstrate
d using wavelength modulation spectroscopy and second harmonic detecti
on. Furthermore,the sensitivity for NH3 was estimated at 0.03 ppm . m
in the 2 mu m region. (C) 1998 Elsevier Science B.V.