Performance of a thermally desorbable type-tube diffusive sampler for verylow air concentrations monitoring

Citation
A. Roche et al., Performance of a thermally desorbable type-tube diffusive sampler for verylow air concentrations monitoring, ATMOS ENVIR, 33(12), 1999, pp. 1905-1912
Citations number
27
Categorie Soggetti
Environment/Ecology,"Earth Sciences
Journal title
ATMOSPHERIC ENVIRONMENT
ISSN journal
13522310 → ACNP
Volume
33
Issue
12
Year of publication
1999
Pages
1905 - 1912
Database
ISI
SICI code
1352-2310(199906)33:12<1905:POATDT>2.0.ZU;2-P
Abstract
Perkin-Elmer tubes packed with Tenax TA have been tested for the monitoring of low concentrations of aromatic compounds and linear alkanes using diffu sive sampling. The uptake rates have been investigated for different exposu re doses. A particular hexane and benzene behaviour has been observed: thei r uptake rates decrease rapidly in the lower exposure doses and so follow a n exponential curve. The uptake rates of heavier compounds adopt another te ndency: a slow decrease with time following a linear profile. The relative humidity influence has been studied too, and no water perturbation has been recorded. (C) 1999 Elsevier Science Ltd. All rights reserved.