We report on 7 patients with pacemaker endocarditis diagnosed during the wo
rkup of long-standing fever. Persistent positive blood cultures and echocar
diography led to the diagnosis in 6 patients whereas autopsy was diagnostic
in another. Causative microorganisms were Staphylococcus epidermidis (3),
Staphylococcus lugdunensis (1), Pseudomonas aeruginosa (1), Streptococcus b
ovis (1), and Streptococcus mitis-Streptococcus sanguis (1), Pulmonary embo
lism was present in nearly 50% of the cases, a figure clearly higher than p
reviously reported. In all but 1 case the initial medical approach was not
successful, and thus the pacing system was finally removed. None of the cas
es relapsed after the removal. We have reviewed the literature regarding pa
cemaker endocarditis, particularly with respect to treatment.