PRELIMINARY STUDIES OF RADIATION COUPLING BETWEEN REMOTE SOFT-X-RAY LASER-AMPLIFIERS

Citation
G. Cairns et al., PRELIMINARY STUDIES OF RADIATION COUPLING BETWEEN REMOTE SOFT-X-RAY LASER-AMPLIFIERS, Applied physics. B, Lasers and optics, 58(1), 1994, pp. 51-56
Citations number
7
Categorie Soggetti
Physics, Applied",Optics
ISSN journal
09462171
Volume
58
Issue
1
Year of publication
1994
Pages
51 - 56
Database
ISI
SICI code
0946-2171(1994)58:1<51:PSORCB>2.0.ZU;2-4
Abstract
Coupling of a soft X-ray laser beam with a relaying concave mirror in a sequentially pumped amplifier geometry using the Ne-like Ge system h as been studied experimentally. Preliminary observations indicate an i ncrease in the spatial coherence of the amplified relayed beam. In add ition, near-field imaging of one of the amplifier plasmas shows a doub le-lobed intensity pattern of the emergent beam indicating refractive guiding of the amplified beam with components both normal and tangenti al to the target surface.