Mh. Guermouche et al., Assay of tinidazole in human serum by high-performance thin-layer chromatography - Comparison with high-performance liquid chromatography, J AOAC INT, 82(2), 1999, pp. 244-247
Determination of tinidazole in human serum by high-performance thin-layer c
hromatography (HPTLC) is presented. It includes use of 10 x 10 cm plates co
ated with silica gel 60 and chloroform-acetonitrile-acetic acid (60 + 40 2) as mobile phase. Quantitation was performed by densitometry at 320 nm, T
he linearity (1-10 ng), precision (6%), reproducibility (5%), recovery (96%
), and detection limit (I mg/L) of tinidazole determination by HPTLC were c
omparable with corresponding method parameters by reversed-phase HPLC. A sa
tisfactory correlation was found between the 2 analytical methods. The proc
edure was used to quantitate tinidazole in patient sera.