PULSE-SHAPE ANALYSIS IN THE LIQUID XENON MULTIWIRE IONIZATION-CHAMBERFOR PET

Citation
P. Crespo et al., PULSE-SHAPE ANALYSIS IN THE LIQUID XENON MULTIWIRE IONIZATION-CHAMBERFOR PET, IEEE transactions on nuclear science, 45(3), 1998, pp. 561-567
Citations number
15
Categorie Soggetti
Nuclear Sciences & Tecnology","Engineering, Eletrical & Electronic
ISSN journal
00189499
Volume
45
Issue
3
Year of publication
1998
Pages
561 - 567
Database
ISI
SICI code
0018-9499(1998)45:3<561:PAITLX>2.0.ZU;2-W
Abstract
A method of computation of the pulse shape in an ionisation chamber wi th wire collectors has been developed and verified experimentally with a test chamber. Good agreement between the calculated waveforms and t he acquired signals is obtained. Having proved its reliability, the sa me method was applied to study the dependence of the signal pulse shap e and amplitude on the location of primary ionisation due to 511 keV g amma-rays in the liquid xenon multiwire ionisation chamber for PET. A method of real-rime amplitude correction for this effect is suggested, resulting in significant improvement of energy resolution. The simula ted resolution for 511 keV gamma-rays is 15%.