TRANSSCLERAL FIXATION OF A DISLOCATED SILICONE PLATE HAPTIC INTRAOCULAR-LENS VIA THE PARS-PLANA

Authors
Citation
L. Akduman, TRANSSCLERAL FIXATION OF A DISLOCATED SILICONE PLATE HAPTIC INTRAOCULAR-LENS VIA THE PARS-PLANA, Ophthalmic surgery, 29(6), 1998, pp. 519-521
Citations number
11
Categorie Soggetti
Ophthalmology,Surgery
Journal title
ISSN journal
0022023X
Volume
29
Issue
6
Year of publication
1998
Pages
519 - 521
Database
ISI
SICI code
0022-023X(1998)29:6<519:TFOADS>2.0.ZU;2-M
Abstract
A method for transscleral fixation of silicone plate haptic posterior chamber intraocular lenses (PC IOLs) via the pars plana is described. One 10-0 polypropylene transscleral suture passed through the sclera a nd the PC IOL hole and a similar suture passed through the sclera only were withdrawn outside the eye through the the pars plana and tied to gether. Pulling up the scleral end of one suture placed the PC IOL hap tic in the sulcus and the knot was pulled outside the eye. Perfluoroca rbon liquid was used during the procedure to safely manipulate the PC IOL. The PC IOL was well centered at 3 months of followup. Posteriorly dislocated silicone plate haptic PC IOLs can be safely sutured to the sclera via the pars plana by this method.