AN LIF LINE SCAN SYSTEM FOR THE MEASUREMENT OF SCALAR CONCENTRATION IN A CONTINUOUSLY OPERATED STIRRED-TANK

Citation
Mfw. Distelhoff et Aj. Marquis, AN LIF LINE SCAN SYSTEM FOR THE MEASUREMENT OF SCALAR CONCENTRATION IN A CONTINUOUSLY OPERATED STIRRED-TANK, Experiments in fluids, 25(1), 1998, pp. 77-88
Citations number
19
Categorie Soggetti
Mechanics,"Engineering, Mechanical
Journal title
ISSN journal
07234864
Volume
25
Issue
1
Year of publication
1998
Pages
77 - 88
Database
ISI
SICI code
0723-4864(1998)25:1<77:ALLSSF>2.0.ZU;2-P
Abstract
An LIF line scan system is presented and used to obtain unobtrusive me an and angle resolved concentration measurements in a continuously ope rated stirred tank agitated with a single Rushton turbine. The measure ments showed that the trailing vortex structures caused regions of ele vated concentrations gradients and concentration fluctuations between blade passages. In addition, on the centre line of the tank, whilst ma cromixing was always complete, micromixing was less complete than in o ther regions of the tank. Compared to point measurement techniques, th e line scan system made data collection more comprehensive and conveni ent and the determination of a line of data allows the possibility of the correction of beam attenuation and the extension of the technique to a larger scale.