HYDRODYNAMIC VOLTAMMETRY WITH MICROELECTRODES - CHANNEL MICROBAND ELECTRODES - THEORY AND EXPERIMENT

Citation
Rg. Compton et al., HYDRODYNAMIC VOLTAMMETRY WITH MICROELECTRODES - CHANNEL MICROBAND ELECTRODES - THEORY AND EXPERIMENT, Journal of physical chemistry, 97(40), 1993, pp. 10410-10415
Citations number
18
Categorie Soggetti
Chemistry Physical
ISSN journal
00223654
Volume
97
Issue
40
Year of publication
1993
Pages
10410 - 10415
Database
ISI
SICI code
0022-3654(1993)97:40<10410:HVWM-C>2.0.ZU;2-H
Abstract
Theory is reported that predicts the mass-transport limited current fl owing at a microband electrode located in a rectangular channel throug h which solution is. pumped under laminar flow conditions. The effect of electrode size and solution flow rate is quantified and the relativ e roles of axial diffusion and convective mass transport are identifie d. Theory is found to be in excellent agreement with experiments condu cted on the reduction of p-chloranil and the oxidation of ferrocene by using gold channel microband electrodes.