G. Pinavillalpando et Dp. Sloan, DOSE DISTRIBUTION STUDIES OF A GAMMA INDUSTRIAL IRRADIATOR USING A PCCODE, Radiation physics and chemistry (1993), 52(1-6), 1998, pp. 563-567
Citations number
5
Categorie Soggetti
Nuclear Sciences & Tecnology","Chemistry Physical","Physics, Atomic, Molecular & Chemical
This paper present a comparison between calculated and experimental ab
sorbed dose values, for a typical product, irradiated in a Co-60 indus
trial irradiator, at lNIN. Such industrial irradiator is two tiers and
two layer systems, with overlapping product to source configuration;
source activity was around 300 kCi. Calculated absorbed dose values we
re obtained by FUGI code, running in a PC microcomputer. This code is
based in a point kernel over the source area, by means of Gauss quadra
ture technique, based in FUDGE-4A code. Build-up factors were estimate
d by Goldstein and Wilkins factors for punctual sources, using Talylor
's approximation formula. Experimental dosimetry data of Petri dishes
packages, with apparent density of 0.13 g/cm(3) data was performed usi
ng red acrylic dosimeters, during irradiation; required minimum dose f
or this material was 15 kGy. Absorbed dose data have shown good approx
imation, particulary a 15% desviation of results from FUGI code. Howev
er, this code can be used for rough calculation of irradiator paramete
rs, before trying to use a more complex and time-consuming code, for d
etailed analysis.