J. Alberdi et al., ENLARGED LINEARITY RANGE OF A RASNIK SYSTEM USING AN INTEGRATING SPHERE, Nuclear instruments & methods in physics research. Section A, Accelerators, spectrometers, detectors and associated equipment, 408(2-3), 1998, pp. 591-593
Rasniks elements are foreseen to be used in the CMS alignment system.
The large displacements and deformations expected for the different su
bdetectors demands large linearity response range of the alignment com
ponents. By the use of an integrating sphere coupled to the light sour
ce, we have optimized the homogenity of the beam, leading to improveme
nt, by factor three, in the linearity range of the Rasnik system with
respect to conventional configurations, preserving the measurement pos
ition resolution. The range obtained coincides with the maximum reacha
ble with the geometry of the used components. (C) 1998 Elsevier Scienc
e B.V. All rights reserved.