HIGH-SENSITIVITY DATA-ACQUISITION DURING STRONG TRANSIENT ELECTROMAGNETIC-FIELDS

Citation
Hu. Muller et al., HIGH-SENSITIVITY DATA-ACQUISITION DURING STRONG TRANSIENT ELECTROMAGNETIC-FIELDS, Physica. B, Condensed matter, 246, 1998, pp. 356-359
Citations number
6
Categorie Soggetti
Physics, Condensed Matter
ISSN journal
09214526
Volume
246
Year of publication
1998
Pages
356 - 359
Database
ISI
SICI code
0921-4526(1998)246:<356:HDDSTE>2.0.ZU;2-Z
Abstract
The 225 kJ 60 kV single-turn coil equipment that recently went into fu ll operation in Berlin, makes it possible to work with magnetic fields above 200 T in a volume of about 1 cm(3). The generation of such high magnetic fields take place on a us-time scale and is therefore connec ted with very strong transient electromagnetic pulses, which considera bly complicate the measuring procedure. This paper describes the techn iques used to record data while taking optical measurements in the inf rared range. (C) 1998 Elsevier Science B.V. All rights reserved.