Analytical study of the needle probe measurement of magnetic nux was p
erformed on the basis of the electromagnetic theory to provide an adva
nced theoretical backbone for the measuring method. Provided that the
nux change in the specimen is homogeneous, the electromotive force ind
uced between the needles represents exactly the nux change in the area
between the needles. The measuring error in the needle probe measurem
ent is caused by lack of homogeneity in the nux change postulated in t
he theory. Among several possible causes of flux non-homogeneity, the
existence of domain structure is most intrinsic in localized area meas
urements, so that in this study the measuring error due to this cause
was calculated theoretically in detail It can be concluded that even i
n the cases of large domain size often occurring in oriented core mate
rials, the localized measurements by the needle probe provide fairly r
eliable measure of the nux change in the area.