Jh. Jeong et al., VISUALIZATION EXPERIMENTS OF THE 2-PHASE FLOW INSIDE A HEMISPHERICAL GAP, International communications in heat and mass transfer, 25(5), 1998, pp. 693-700
Experiments have been carried out in order to visualize the behaviour
of a two-phase flow inside a hemispherical narrow gap. The test facili
ty consists of a hemispherical heater and a pyrex-glass bell-jar-shape
d vessel. The transparent pyrex-glass vessel was intended to make a 1
mm gap between the heater and itself but the gap size was not uniform
because of manufacturing difficulties. The incoming water and escaping
steam flowed in counter-directions through separated flow paths. As t
he heater power increased, the escaping steam velocity increased and f
inally reached the counter-current flow limit(CCFL). The CCFL occurred
at the location where the top-end gap size is smaller compared to the
other part. Just below the top-end where the CCFL occurred, the heate
r surface was found to be locally dried out. (C) 1998 Elsevier Science
Ltd.