HAMMING SIGNATURE OF 3 COMPOSITE SPECIMENS

Authors
Citation
P. Munshi et Sp. Singh, HAMMING SIGNATURE OF 3 COMPOSITE SPECIMENS, Research in nondestructive evaluation, 10(2), 1998, pp. 109-122
Citations number
12
Categorie Soggetti
Materials Science, Characterization & Testing
ISSN journal
09349847
Volume
10
Issue
2
Year of publication
1998
Pages
109 - 122
Database
ISI
SICI code
0934-9847(1998)10:2<109:HSO3CS>2.0.ZU;2-X
Abstract
Three samples having composite structure are examined by an X-ray tomo graphic scanner for pixel sizes of 20 to 160 mu m. The data are proces sed by the convolution backprojection algorithm and the resulting tomo graphic images are analyzed for the Hamming class of filters. The char acteristic signature of the three specimens is interpreted with the he lp of two error theorems.