Ba. Welt et al., UTILIZATION OF MICROWAVES IN THE STUDY OF REACTION-KINETICS IN LIQUIDAND SEMISOLID MEDIA, Biotechnology progress, 9(5), 1993, pp. 481-487
An apparatus, referred to as the microwave kinetics reactor (MWKR), in
corporating a microwave-transparent pressure vessel with mechanical mi
xing together with a microwave temperature controller, was developed a
nd tested. Experiments were performed to determine a safe and practica
l operating envelope for the MWKR. Temperatures measured at the center
and at the top surface of varying viscosity solutions in the MWKR wer
e used to determine the adequacy of mixing when the solutions were hea
ted from room temperature to 120-degrees-C and held for a prescribed p
eriod of time. The viscosities of the solutions were adjusted by addin
g (carboxymethyl)cellulose (CMC) to distilled water. A 2% CMC solution
represented the upper viscosity limit to be heated homogeneously in t
he apparatus (approximately 2000 cP). To illustrate the usefulness of
this apparatus in obtaining kinetic parameters, thiamin hydrochloride
degradation kinetics in pea puree were determined at 100, 120, and 130
-degrees-C and compared to those obtained from the literature. The MWK
R offers an attractive, efficient, convenient, and accurate alternativ
e for the study of reaction kinetics in viscous fluids and semisolids
because of its short come-up time and mixing capability. Experimentall
y determined kinetic parameters compared very well to those obtained f
rom the literature. As expected the kinetics was first-order, with an
activation energy, E(a), of 27.0 kcal/mol.