THE LEACHING OF NICKEL FROM NEW AND USED METAL SPECTACLE FRAMES

Citation
G. Walsh et Jwc. Mitchell, THE LEACHING OF NICKEL FROM NEW AND USED METAL SPECTACLE FRAMES, Ophthalmic & physiological optics, 18(4), 1998, pp. 372-377
Citations number
26
Categorie Soggetti
Ophthalmology
ISSN journal
02755408
Volume
18
Issue
4
Year of publication
1998
Pages
372 - 377
Database
ISI
SICI code
0275-5408(1998)18:4<372:TLONFN>2.0.ZU;2-9
Abstract
Fifty ''used'' and 373 new spectacle frames were tested for evidence o f nickel release using dimethylglyoxime and ammonia. Nearly all the '' used'' frames (96%) tested positive. A lower proportion (24.5%) of new frames showed evidence of nickel leaching. It is suggested that this is evidence of non-conformance with the current British Standard altho ugh all our suppliers believed that their frames conformed with BS 662 5 (1985). (C) 1998 The College of Optometrists. Published by Elsevier Science Ltd. All rights reserved.