EFFECT OF A RADIANT BARRIER ON THE COOLING LOAD OF A RESIDENTIAL APPLICATION IN A HOT AND ARID REGION - ATTIC DUCT EFFECT

Citation
Sf. Moujaes et Ra. Brickman, EFFECT OF A RADIANT BARRIER ON THE COOLING LOAD OF A RESIDENTIAL APPLICATION IN A HOT AND ARID REGION - ATTIC DUCT EFFECT, HVAC&R research, 4(3), 1998, pp. 231-244
Citations number
21
Categorie Soggetti
Construcion & Building Technology","Engineering, Mechanical",Thermodynamics
Journal title
ISSN journal
10789669
Volume
4
Issue
3
Year of publication
1998
Pages
231 - 244
Database
ISI
SICI code
1078-9669(1998)4:3<231:EOARBO>2.0.ZU;2-J
Abstract
A computer simulation showed that an attic radiant barrier system (RBS ) (a commercial product laminated to the underside of the roof sheathi ng) significantly reduces cooling load requirements in hot desert clim ates. This reduction was due to both a reduction in sensible hear tran sfer through the ceiling and an even greater reduction in losses (heat pickup) by the HVAC ducting system in the attic. These reductions wer e around 16% in runtime over the daytime hours and an overall 9% reduc tion over a five-day period. This latter effect indicates the need to improve current duct-loss calculation methods.