PREPARATION OF CARRIER-FREE Y-90 FOR MEDICAL APPLICATIONS BY SOLVENT-EXTRACTION CHROMATOGRAPHY

Citation
Bt. Hsieh et al., PREPARATION OF CARRIER-FREE Y-90 FOR MEDICAL APPLICATIONS BY SOLVENT-EXTRACTION CHROMATOGRAPHY, Applied radiation and isotopes, 44(12), 1993, pp. 1473-1480
Citations number
30
Categorie Soggetti
Nuclear Sciences & Tecnology","Radiology,Nuclear Medicine & Medical Imaging
Journal title
Applied radiation and isotopes
ISSN journal
09698043 → ACNP
Volume
44
Issue
12
Year of publication
1993
Pages
1473 - 1480
Database
ISI
SICI code
0969-8043(1993)44:12<1473:POCYFM>2.0.ZU;2-G
Abstract
The separation of carrier-free Y-90 from fission product Sr-90 by soli d supported solvent extraction chromatography was investigated using T eflon grain as solid support and a di-(2-ethylhexyl) phosphoric acid ( D2EHPA) extraction agent as liquid phase. The optimum separation condi tions are: (1) solid support using Dupont TF800 Teflon grains, (2) usi ng 5% D2EHPA ''traction agent as liquid phase, (3) setting the flow ra te. at 1 cm3/min; and (4) using a column diameter of 0.5 cm which was packed with 1 g treated Teflon. After loading Sr-90/Y-90 equilibrium s olution, the loaded column was washed with 0.3 N hydrochloric acid to remove Sr-90 species; subsequently, 8 N hydrochloric acid was used as an eluent to obtain a Y-90 solution. Chemical yield was about 90%; rad ionuclide impurity of Sr-90 in the final product was < 10(-6)%. Conseq uently, the preparation of 1 mCi of Y-90 was satisfactory for radiolab eling in medical applications. A radiotracer method using Sr-85 and Y- 88 was also developed to investigate separation efficiency.