A simple equation of state (EOS) applicable to defining autoclave test
environments was developed. The approach is particularly helpful when
mixed gases (carbon dioxide [CO2]/hydrogen sulfide [H2S]) must be use
d. Test liquids may consist of an aqueous and a hydrocarbon phase, or
the gases may be added at room temperature (RT) prior to heat-up. Solu
bilities for CO2 and H2S in various liquids have been reviewed and dat
a verifying the EOS presented. A sensitivity analysis reviewed the eff
ects of possible misassessment of the solubilities, and comments have
been made regarding the process of preparing test environments in pres
sure vessels.