An analysis is made of the maximum power multiplication factor Q, achi
evble in subignited Tokamak fusion plasmas where the burn is sustained
by feedback controlled auxiliary heating. Using a 1-D model equation
for the plasma temperature, simple analytical expressions are derived
for the scaling of the maximum Q with relevant physical parameters. Th
e results are also corroborated by comparison with numerical computati
ons.