INDOOR AIR-POLLUTION DUE TO INTEGRATED GARAGES

Citation
I. Schaefer et S. Luther, INDOOR AIR-POLLUTION DUE TO INTEGRATED GARAGES, Gefahrstoffe, Reinhaltung der Luft, 58(7-8), 1998, pp. 307-312
Citations number
6
Categorie Soggetti
Environmental Sciences","Engineering, Civil","Engineering, Environmental
ISSN journal
09498036
Volume
58
Issue
7-8
Year of publication
1998
Pages
307 - 312
Database
ISI
SICI code
0949-8036(1998)58:7-8<307:IADTIG>2.0.ZU;2-J
Abstract
The paper presented did some research on the indoor air pollution due to integrated garages. For that purpose the health offices Bremen and Bremen-North investigated organic substances like benzene, toluene and xylene in 47 selected flats. The measuring was done using passive sam pling tubes over a period of two weeks. The analysis was carried out i n an external laboratory by gas chromatography. The results indicate t hat - dependent on the positions and the dimensions of the garages - i ndoor air pollution with organic chemicals exists in adjacent flats at known level. In isolated cases a remarkable decline of the quality of the indoor air was measured mainly due to the construction of the bui ldings. Because of the unhealthy carcinogenic potential of benzene pre ventive precautions for the environmental health are required. There i s no generally indoor air pollution due to integrated garages. But in case of a complaint the health offices should check the particular sit uation. For new constructions adequate ventilation should be a must.