The present payer tries to contribute to quantifying the relationship
between the amount of corrosion and cover cracking. The variables stud
ied were: cover/diameter (c/<empty set>), proportions of cement, w/c,
cast position of the bar, transverse reinforcement and corrosion rate.
The corrosion is accelerated by applying constant currents causing th
e rebar to act as an anode. The results indicate that the cracking pro
cess develops in two steps: generation and propagation. Radius losses
of about 15-50 mu m are necessary to generate the first visible crack
(< 0.1 mm width). The propagation follows a behaviour of the type: w (
crack width in mm) = a + bx (radius loss in mu m).