K. Ohashi et al., PRELIMINARY-STUDY ON THE APPLICATION OF THE HEAT-PIPE TO THE PASSIVE DECAY HEAT REMOVAL SYSTEM OF THE MODULAR HTR, Progress in nuclear energy (New series), 32(3-4), 1998, pp. 587-594
To investigate the applicability of heat pipe to the decay hat removal
(DHR) system of the modular HTRs, preliminary study of the Heat Pipe
DHR System was performed. The results show that the Heat Pipe DHR Syst
em is applicable to the modular HTRs and its heat removal capability i
s sufficient. Especially, by applying the variable conductance heat pi
pe, possibility of a fully passive DHR system with lower heat loss dur
ing normal operation is suggested. The experiments to obtain the funda
mental characteristics data of the variable conductance heat pipe were
carried out and the experimental results are also shown. (C) 1997 Pub
lished by Elsevier Science Ltd.