A. Paneque et al., HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHIC METHOD FOR THE DETERMINATION OF LOBENZARIT DISODIUM IN A SUSTAINED-RELEASE TABLET FORMULATION, Arzneimittel-Forschung, 48(8), 1998, pp. 832-835
A rapid and simple high performance liquid chromatographic method is d
escribed and validated for the determination of lobenzarit disodium (C
AS 64808-48-6) in a sustained release tablet formulation. The calibrat
ion graph was linear over the range 20-105 mu g/ml. The sensitivity (d
iscriminator capacity) was 2.079 mu g/ml. The coefficient of variation
s for repeatability and reproducibility were less than 1.60% and 1.30%
, respectively. The accuracy of the method did not depend on lobenzari
t concentration in tablets. The mean recovery was found to be 100.62%.
The method was selective, even when degradation products were present
.