B. Vandenbrandt et al., STATUS-REPORT ON THE ORPHEUS DARK-MATTER DETECTOR AND ON ITS SQUID READOUT SYSTEM, Nuclear physics. B, Proceedings supplement, 70, 1999, pp. 101-105
We report the status of the ORPHEUS dark matter experiment. The detect
or will consist of about 1 kg of superheated superconducting Tin granu
les and will be operated below 0.5 K. Measurements with a 32 cm(3) tar
get, read by a single SQUID channel, are presented. Experience has bee
n gained with cryogenic tests, performed with a test detector chamber,
mounted via a side access to the cryostat.