K. Hwang et al., SIMULTANEOUS ANALYSIS OF SILVER PLATING BATH COMPRISING SLIVER CYANIDE, PHOSPHATE AND MERCAPTOBENZOTHIAZOLE DERIVATIVES USING A CAPILLARY ION ANALYZER, Plating and surface finishing, 85(10), 1998, pp. 74-76
Citations number
11
Categorie Soggetti
Metallurgy & Metallurigical Engineering","Materials Science, Coatings & Films
PSC (potassium silver cyanide), anionic surfactant and HPO4-2 componen
ts consisting of Ag plating solutions were simultaneously analyzed wit
h a capillary ion analyzer, using a phthalate buffer at pH 5.6. Detect
ion of each ion was achieved using on-column indirect photometry at 25
4 nm. Quantities of PSC, HPO4-2 and mercaptobenzothiazole derivatives
were found to be about 1.6 g/L, 0.6 g/L and 0.2 (v/v) percent, respect
ively, in the artificial silver plating solution,compared with a stand
ard solution, The three components were analyzed without affecting oth
er components, such as surfactants and cyanide. This simultaneous anal
ysis method for silver plating solutions is a very powerful technique
for process control systems.