PERFORMANCE ANALYSIS OF DOUBLE STACK COLD PLATES COVERING ALL CONDITIONS OF ASYMMETRIC HEAT LOADING

Citation
Rj. Pieper et Ad. Kraus, PERFORMANCE ANALYSIS OF DOUBLE STACK COLD PLATES COVERING ALL CONDITIONS OF ASYMMETRIC HEAT LOADING, Journal of electronic packaging, 120(3), 1998, pp. 296-301
Citations number
18
Categorie Soggetti
Engineering, Mechanical","Engineering, Eletrical & Electronic
ISSN journal
10437398
Volume
120
Issue
3
Year of publication
1998
Pages
296 - 301
Database
ISI
SICI code
1043-7398(1998)120:3<296:PAODSC>2.0.ZU;2-M
Abstract
Double stack, force-cooled cold plates, which are used as electronic c hassis, are investigated for all conditions of unequal temperature and heat loading. A closed form solution that relates the plate temperatu res to composite heat loads is derived. This analysis covers all regim es of operation. In particular, this includes the previously ignored r egime in which no adiabatic point exists anywhere on either of the fin s connecting cover and splitter plates, The heat dissipating advantage of the double stack structure, over a similarly designed single stack structure, is predicted with the analysis presented in the paper.