APPLICATION OF MEMBRANE TECHNOLOGY FOR DRINKING-WATER

Citation
Wt. Ma et al., APPLICATION OF MEMBRANE TECHNOLOGY FOR DRINKING-WATER, Desalination, 119(1-3), 1998, pp. 127-131
Citations number
NO
Categorie Soggetti
Water Resources","Engineering, Chemical
Journal title
ISSN journal
00119164
Volume
119
Issue
1-3
Year of publication
1998
Pages
127 - 131
Database
ISI
SICI code
0011-9164(1998)119:1-3<127:AOMTFD>2.0.ZU;2-9
Abstract
In order to provide high-quality drinking water to the residents, Daqi ng City started the High-Quality Water Supply Project in 1994. In the first phase, seven polishing water treatment systems consisting of pre ozonation, microfiltration (MF), activated carbon (AC) adsorption, ult rafiltration (UF) or reverse osmosis (RO) and postozonation were insta lled in various residential districts. The existing low-quality tap wa ter is used as feed water, and the treated water is distributed to the customers through an independent network or with bottles for drinking and cooking purposes. The total treatment capacity of the seven syste ms is 620 m(3)/d. The seven systems were commissioned separately from September to November 1997 and have been running smoothly. The perform ance of the systems meets the design requirements, and the treated wat er quality meets the European Union Drinking Water Standard. Economica lly, both capital investment and operating costs are within the initia l budgets and at rational levels.