Cd. Garcia et Pi. Ortiz, DETERMINATION OF TERT-BUTYLHYDROXYTOLUENE BY FLOW-INJECTION ANALYSIS AT POLYMER-MODIFIED GLASSY-CARBON ELECTRODES, Electroanalysis, 10(12), 1998, pp. 832-835
A flow injection method for the determination of the antioxidant BHT u
sing polymer modified electrodes in connection with amperometric detec
tion is proposed. The procedure is based on the electrochemical oxidat
ion at 0.700 V (vs. Ag/AgCl[3M NaCl]) in phosphate buffer solution (pH
7.2). BHT is determined over the range 0.001-0.020 or 0.005-0.030 gL(
-1). Other analytical parameters, such as electrode working potential,
flow rate, electrodeposited charge and solution pH were optimized. Th
e proposed method was applied to the determination of BHT in electrica
l transformer and vegetable oils samples. The results were compared wi
th the HPLC-UV detection standard technique.