Ja. Morley et al., Determination of the endothelin receptor antagonist ABT-627 and related substances by high performance liquid chromatography, J PHARM B, 19(5), 1999, pp. 777-784
The determination of the endothelin (ET) antagonist receptor ABT-627 (I) an
d related substances is performed by HPLC. I is determined in bulk drug sub
stance and drug formulation using isocratic conditions and an Inertsil ODS-
2 column. The determination is stability indicating and detector response i
s linear from 24 to 118 mu g ml(-1) (33-164% of assay level). Intermediate
precision for the determination ranged from +/- 0.60 to +/- 1.9% RSD. The m
easurement is accurate, with quantitative recovery of I from the formulatio
n placebo. Related substances in I and formulated I are determined using th
e same chromatographic conditions, with a gradient elution profile to elute
impurities having varying relative polarities. The detector response for r
elated substances determination is linear for I from 0.60 to 17.8 mu g ml(-
1) (0.05-1.5% of assay level) with the limit of detection and quantitation
estimated at 0.01 and 0.05%, respectively. Comparable precision was obtaine
d in drug substance and drug formulation (RSD values +/- 3.7 to +/- 12% and
+/- 5.5 to 16.9%, respectively for impurities ranging from 0.05 to 0.30%).
The quantitated impurities agreed well for the same lot of I when assayed
as a bulk substance and after the formulation into a drug product. (C) 1999
Elsevier Science B.V. All rights reserved.