Pressure transducer mounts for internal blast measurements on thin metal walls

Citation
G. Yiannakopoulos et P. Kiernan, Pressure transducer mounts for internal blast measurements on thin metal walls, REV SCI INS, 70(4), 1999, pp. 2122-2126
Citations number
4
Categorie Soggetti
Spectroscopy /Instrumentation/Analytical Sciences","Instrumentation & Measurement
Journal title
REVIEW OF SCIENTIFIC INSTRUMENTS
ISSN journal
00346748 → ACNP
Volume
70
Issue
4
Year of publication
1999
Pages
2122 - 2126
Database
ISI
SICI code
0034-6748(199904)70:4<2122:PTMFIB>2.0.ZU;2-C
Abstract
Three mounts are described for installing pressure transducers on thin wall s for internal blast measurements in which the walls undergo ductile ruptur e. Details of the mounts are presented and each mount is evaluated from sev eral examples of pressure-time profiles obtained from thin steel walled cub es and ship compartment studies. Two designs proved effective, one having a flange and a sheath to protect the transducer, and another, a simpler and lighter design, consisting of a welded ring. (C) 1999 American Institute of Physics. [S0034-6748(99)05104-7].