Effect of the cylindrical surface of the component in ultrasound inspection with an inclined transducer

Citation
Vn. Danilov et Vm. Ushakov, Effect of the cylindrical surface of the component in ultrasound inspection with an inclined transducer, RUSS J NOND, 34(8), 1998, pp. 566-571
Citations number
4
Categorie Soggetti
Material Science & Engineering
Journal title
RUSSIAN JOURNAL OF NONDESTRUCTIVE TESTING
ISSN journal
10618309 → ACNP
Volume
34
Issue
8
Year of publication
1998
Pages
566 - 571
Database
ISI
SICI code
1061-8309(199808)34:8<566:EOTCSO>2.0.ZU;2-3
Abstract
The results of theoretical and experimental investigations of the cylindric al surface of the component on the signal of a combined inclined transducer are compared. The presence of local extrema of the amplitude of the signal in relation to the degree of fitting of the prism of the transducer is con firmed.