Sd. Hill et al., APPLICATION OF CASING TREATMENT TO AN INDUSTRIAL AXIAL-FLOW FAN, Proceedings of the Institution of Mechanical Engineers. Part A, Journal of power and energy, 212(A4), 1998, pp. 225-233
This paper deals with an experimental investigation into the influence
of a vaned recess casing treatment on the performance of an industria
l-type axial-flow fan with a hub-tip ratio of 0.4. The treatment has b
een tested in a variety of configurations relative to the fan, with an
emphasis on the amount of fan blade tip exposure to the treatment. Tw
o sets of blading, one of which is of the fully reversible type, have
been investigated. Detailed flow measurements have been carried out wi
th a slanted hot wire probe to provide an insight into the operation o
f the device and into the nature of the rotating stall in the solid ca
sing configuration. Strain gauges have been employed to enable blade s
tresses to be recorded and an in-duct microphone to enable comparative
tests on fan noise has also been used.